Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 253
Filtrar
1.
Mol Cell Proteomics ; : 100760, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38579929

RESUMO

We describe deep analysis of the human proteome in less than one hour. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high MS/MS acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data independent- or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis (DIA) methods. Over a 30-minute active chromatographic method consuming a total analysis time of 56 minutes, the Q-Orbitrap-Astral hybrid MS collects an average of 4,319 MS1 scans and 438,062 MS/MS scans per run, producing 235,916 peptide sequences (1% false discovery rate (FDR)). On average, each 30-minute analysis achieved detection of 10,411 protein groups (1% FDR). We conclude, with these results and alongside other recent reports, that the one-hour human proteome is within reach.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38609335

RESUMO

Traditionally, mass spectrometry (MS) output is the ion abundance plotted versus the ionic mass-to-charge ratio m/z. While employing only commercially available equipment, Charge Determination Analysis (CHARDA) adds a third dimension to MS, estimating for individual peaks their charge states z starting from z = 1 and color coding z in m/z spectra. CHARDA combines the analysis of ion signal decay rates in the time-domain data (transients) in Fourier transform (FT) MS with the interrogation of mass defects (fractional mass) of biopolymers. Being applied to individual isotopic peaks in a complex protein tandem (MS/MS) data set, CHARDA aids peptide mass spectra interpretation by facilitating charge-state deconvolution of large ionic species in crowded regions, estimating z even in the absence of an isotopic distribution (e.g., for monoisotopic mass spectra). CHARDA is fast, robust, and consistent with conventional FTMS and FTMS/MS data acquisition procedures. An effective charge-state resolution Rz ≥ 6 is obtained with the potential for further improvements.

3.
Anal Chem ; 96(14): 5392-5398, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38526848

RESUMO

Along with mass spectrometry (MS), ion mobility separations (IMS) are advancing to ever larger biomolecules. The emergence of electrospray ionization (ESI) and native MS enabled the IMS/MS analyses of proteins up to ∼100 kDa in the 1990s and whole protein complexes and viruses up to ∼10 MDa since the 2000s. Differential IMS (FAIMS) is substantially orthogonal to linear IMS based on absolute mobility K and offers exceptional resolution, unique selectivity, and steady filtering readily compatible with slower analytical methods such as electron capture or transfer dissociation (ECD/ETD). However, the associated MS stages had limited FAIMS to ions with m/z < 8000 and masses under ∼300 kDa. Here, we integrate high-definition FAIMS with the Q-Exactive Orbitrap UHMR mass spectrometer that can handle m/z up to 80,000 and MDa-size ions in the native ESI regime. In the initial evaluation, the oligomers of monoclonal antibody adalimumab (148 kDa) are size-selected up to at least the nonamers (1.34 MDa) with m/z values up to ∼17,000. This demonstrates the survival and efficient separation of noncovalent MDa assemblies in the FAIMS process, opening the door to novel analyses of the heaviest macromolecules.


Assuntos
Espectrometria de Mobilidade Iônica , Proteínas , Espectrometria de Massas/métodos , Proteínas/química , Íons
4.
Nat Methods ; 21(4): 619-622, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38443506

RESUMO

Orbitrap-based charge detection mass spectrometry utilizes single-molecule sensitivity to enable mass analysis of even highly heterogeneous, high-mass macromolecular assemblies. For contemporary Orbitrap instruments, the accessible ion detection (recording) times are maximally ~1-2 s. Here by modifying a data acquisition method on an Orbitrap ultrahigh mass range mass spectrometer, we trapped and monitored individual (single) ions for up to 25 s, resulting in a corresponding and huge improvement in signal-to-noise ratio (×5 compared with 1 s), mass resolution (×25) and accuracy in charge and mass determination of Orbitrap-based charge detection mass spectrometry.


Assuntos
Espectrometria de Massas , Espectrometria de Massas/métodos , Análise Espectral , Íons
5.
Front Mol Neurosci ; 17: 1362581, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38516041

RESUMO

One of the hallmarks of Alzheimer's disease (AD) is the accumulation of beta-amyloid peptide (Aß) leading to formation of soluble neurotoxic Aß oligomers and insoluble amyloid plaques in various parts of the brain. Aß undergoes post-translational modifications that alter its pathogenic properties. Aß is produced not only in brain, but also in the peripheral tissues. Such Aß, including its post-translationally modified forms, can enter the brain from circulation by binding to RAGE and contribute to the pathology of AD. However, the transport of modified forms of Aß across the blood-brain barrier (BBB) has not been investigated. Here, we used a transwell BBB model as a controlled environment for permeability studies. We found that Aß42 containing isomerized Asp7 residue (iso-Aß42) and Aß42 containing phosphorylated Ser8 residue (pS8-Aß42) crossed the BBB better than unmodified Aß42, which correlated with different contribution of endocytosis mechanisms to the transport of these isoforms. Using microscale thermophoresis, we observed that RAGE binds to iso-Aß42 an order of magnitude weaker than to Aß42. Thus, post-translational modifications of Aß increase the rate of its transport across the BBB and modify the mechanisms of the transport, which may be important for AD pathology and treatment.

6.
J Mass Spectrom ; 59(4): e5006, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38501497

RESUMO

Space charge effects are the Achilles' heel of all high-resolution ion optical devices. In time-of-flight mass analyzers, these may manifest as reduction of resolving power, mass measurement shift, peak coalescence, and/or transmission losses, while highly sensitive modern ion sources and injection devices ensure that such limits are easily exceeded. Space charge effects have been investigated, by experiment and simulation study, for the astral multi-reflection analyzer, incorporating ion focusing via a pair of converging ion mirrors, and fed by a pulsed extraction ion trap. Major factors were identified as the resonant effect between ~103 ions of similar m/z in-flight and the expansion of trapped packets of ~104-5 ions prior to extraction. Optimum operation and compensated ion mirror calibration strategies were then generated and described based on these findings.

7.
Rapid Commun Mass Spectrom ; 38(6): e9657, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38342682

RESUMO

RATIONALE: Characterization of Regolith And Trace Economic Resources (CRATER), an Orbitrap™-based laser desorption mass spectrometry instrument designed to conduct high-precision, spatially resolved analyses of planetary materials, is capable of answering outstanding science questions about the Moon's formation and the subsequent processes that have modified its (sub)surface. METHODS: Here, we describe the baseline design of the CRATER flight model, which requires <20 000 cm3  volume, <10 kg mass, and <60 W peak power. The analytical capabilities and performance metrics of a prototype that meets the full functionality of the flight model are demonstrated. RESULTS: The instrument comprises a high-power, solid-state, pulsed ultraviolet (213 nm) laser source to ablate the surface of the lunar sample, a custom ion optical interface to accelerate and collimate the ions produced at the ablation site, and an Orbitrap mass analyzer capable of discriminating competing isobars via ultrahigh mass resolution and high mass accuracy. The CRATER instrument can measure elemental and isotopic abundances and characterize the organic content of lunar surface samples, as well as identify economically valuable resources for future exploration. CONCLUSION: An engineering test unit of the flight model is currently in development to serve as a pathfinder for near-term mission opportunities.

8.
Nat Biotechnol ; 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302753

RESUMO

Mass spectrometry (MS)-based proteomics aims to characterize comprehensive proteomes in a fast and reproducible manner. Here we present the narrow-window data-independent acquisition (nDIA) strategy consisting of high-resolution MS1 scans with parallel tandem MS (MS/MS) scans of ~200 Hz using 2-Th isolation windows, dissolving the differences between data-dependent and -independent methods. This is achieved by pairing a quadrupole Orbitrap mass spectrometer with the asymmetric track lossless (Astral) analyzer which provides >200-Hz MS/MS scanning speed, high resolving power and sensitivity, and low-ppm mass accuracy. The nDIA strategy enables profiling of >100 full yeast proteomes per day, or 48 human proteomes per day at the depth of ~10,000 human protein groups in half-an-hour or ~7,000 proteins in 5 min, representing 3× higher coverage compared with current state-of-the-art MS. Multi-shot acquisition of offline fractionated samples provides comprehensive coverage of human proteomes in ~3 h. High quantitative precision and accuracy are demonstrated in a three-species proteome mixture, quantifying 14,000+ protein groups in a single half-an-hour run.

9.
Chempluschem ; : e202300736, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332534

RESUMO

The title radical R⋅, synthesized by reduction of the corresponding cation R+ , is thermally stable up to ~380 K in the crystalline state under anaerobic conditions. With SQUID magnetometry, single-crystal and powder XRD, solid-state EPR and TG-DSC, reversible spin-Peierls transition between diamagnetic and paramagnetic states featuring ~10 K hysteretic loop is observed for R⋅ in the temperature range ~310-325 K; ΔH=~2.03 kJ mol-1 and ΔS=~6.23 J mol-1 K-1 . The transition is accompanied by mechanical movement of the crystals, i. e., by thermosalient behavior. The low-temperature diamagnetic P-1 polymorph of R⋅ consists of R⋅2 π-dimers arranged in (…R⋅2 …)n π-stacks; whereas the high-temperature paramagnetic P21 /c polymorph, of uniform (…R⋅…)n π-stacks. With the XRD geometries, CASSCF and broken-symmetry DFT jointly suggest strong antiferromagnetic (AF) interactions within R⋅2 and weak between R⋅2 for the (…R⋅2 …)n stacks; and moderate AF interactions between R⋅ for the (…R⋅…)n stacks. The fully hydrocarbon archetype of R⋅ does not reveal the aforementioned properties. Thus, the fluorinated 1,3,2-benzodithiazolyls pave a new pathway in the design and synthesis of metal-less magnetically-bistable materials.

10.
Sci Adv ; 10(7): eadl4628, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38354247

RESUMO

Native mass spectrometry (MS) has become widely accepted in structural biology, providing information on stoichiometry, interactions, homogeneity, and shape of protein complexes. Yet, the fundamental assumption that proteins inside the mass spectrometer retain a structure faithful to native proteins in solution remains a matter of intense debate. Here, we reveal the gas-phase structure of ß-galactosidase using single-particle cryo-electron microscopy (cryo-EM) down to 2.6-Å resolution, enabled by soft landing of mass-selected protein complexes onto cold transmission electron microscopy (TEM) grids followed by in situ ice coating. We find that large parts of the secondary and tertiary structure are retained from the solution. Dehydration-driven subunit reorientation leads to consistent compaction in the gas phase. By providing a direct link between high-resolution imaging and the capability to handle and select protein complexes that behave problematically in conventional sample preparation, the approach has the potential to expand the scope of both native mass spectrometry and cryo-EM.


Assuntos
Proteínas , Manejo de Espécimes , Microscopia Crioeletrônica/métodos , Proteínas/química , Espectrometria de Massas/métodos , beta-Galactosidase , Manejo de Espécimes/métodos
11.
J Chem Inf Model ; 64(3): 918-932, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38241093

RESUMO

Beta amyloid peptide Aß 1-42 (Aß42) has a unique dual role in the human organism, as both the peptide with an important physiological function and one of the most toxic biological compounds provoking Alzheimer's disease (AD). There are several known Aß42 isoforms that we discuss here that are highly neurotoxic and lead to the early onset of AD. Aß42 is an intrinsically disordered protein with no experimentally solved structure under physiological conditions. The objective of this research was to establish the appropriate molecular dynamics (MD) methodology and model a uniform set of structures for the Aß42 isoforms that form the core of this study. For that purpose, force field selection and verification including convergence testing for MD simulations was made. Replica exchange MD and conventional MD modeling of several Aß42 and Aß16 isoforms that have neurotoxic and amyloidogenic effects impacting the severity of Alzheimer's disease were carried out with the optimal force field and solvent parameters. A standardized ensemble of structures for the Aß42 and Aß16 isoforms covering 30-50% of the conformational ensembles extracted from the free energy minima was calculated from MD trajectories. The resulting data set of modeled structures includes Aß42 wild type, isoD7, pS8, D7H, and H6R-Aß42 and Aß16 wild type, isoD7, pS8, D7H, and H6R-Aß16. The representative structures are given in the Supporting Information; they are open for public access. In the study, we also evaluated the differences between the structures of Aß42 isoforms and speculate on their possible relevance to the known functions. Utilizing several representative structures for a single disordered protein for docking, with their subsequent averaging by conformations, would markedly increase the reliability of docking results.


Assuntos
Doença de Alzheimer , Peptídeos beta-Amiloides , Humanos , Peptídeos beta-Amiloides/química , Simulação de Dinâmica Molecular , Doença de Alzheimer/metabolismo , Reprodutibilidade dos Testes , Isoformas de Proteínas/metabolismo , Fragmentos de Peptídeos/química , Amiloide
12.
Mol Cell Proteomics ; 23(2): 100713, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38184013

RESUMO

Optimizing data-independent acquisition methods for proteomics applications often requires balancing spectral resolution and acquisition speed. Here, we describe a real-time full mass range implementation of the phase-constrained spectrum deconvolution method (ΦSDM) for Orbitrap mass spectrometry that increases mass resolving power without increasing scan time. Comparing its performance to the standard enhanced Fourier transformation signal processing revealed that the increased resolving power of ΦSDM is beneficial in areas of high peptide density and comes with a greater ability to resolve low-abundance signals. In a standard 2 h analysis of a 200 ng HeLa digest, this resulted in an increase of 16% in the number of quantified peptides. As the acquisition speed becomes even more important when using fast chromatographic gradients, we further applied ΦSDM methods to a range of shorter gradient lengths (21, 12, and 5 min). While ΦSDM improved identification rates and spectral quality in all tested gradients, it proved particularly advantageous for the 5 min gradient. Here, the number of identified protein groups and peptides increased by >15% in comparison to enhanced Fourier transformation processing. In conclusion, ΦSDM is an alternative signal processing algorithm for processing Orbitrap data that can improve spectral quality and benefit quantitative accuracy in typical proteomics experiments, especially when using short gradients.


Assuntos
Proteoma , Espectrometria de Massas em Tandem , Humanos , Proteoma/metabolismo , Espectrometria de Massas em Tandem/métodos , Peptídeos/análise , Células HeLa , Proteômica/métodos
13.
J Am Soc Mass Spectrom ; 35(1): 74-81, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-37925680

RESUMO

Ion traps are routinely directly coupled to mass analyzers, where they serve to suitably cool and shape an ion population prior to pulsed extraction into the analyzer proper. Such devices benefit from high duty cycle and transmission but suffer slow ion processing times caused by a compromise in the buffer gas pressure range that suitably dampens the ion kinetic energy without causing excessive scatter during extraction or within the analyzer. A rectilinear RF quadrupole ion trap has been characterized, conjoining a pressurized collision region with a pumped extraction region, and an unbroken RF interface for seamless ion transfer between them. Auxiliary electrodes mounted between the RF electrodes provide DC voltage gradients that serve to both guide ions through the device and position them at the extraction slot. The influence of the auxiliary DC upon the trapping RF field was measured, and suitable parameters were defined. A mode of operation was developed that allowed parallel processing of ions in both regions, enabling a repetition rate of 200 Hz when the device was coupled to a high-resolution accurate-mass analyzer.

14.
Anal Chem ; 96(1): 127-136, 2024 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-38126724

RESUMO

In vitro/in vivo detection of copper ions is a challenging task but one which is important in the development of new approaches to the diagnosis and treatment of cancer and hereditary diseases such as Alzheimer's, Wilson's, etc. In this paper, we present a nanopipette sensor capable of measuring Cu2+ ions with a linear range from 0.1 to 10 µM in vitro and in vivo. Using the gold-modified nanopipette sensor with a copper chelating ligand, we evaluated the accumulation ability of the liposomal form of an anticancer Cu-containing complex at three levels of biological organization. First, we detected Cu2+ ions in a single cell model of human breast adenocarcinoma MCF-7 and in murine melanoma B16 cells. The insertion of the nanoelectrode did not result in leakage of the cell membrane. We then evaluated the distribution of the Cu-complex in MCF-7 tumor spheroids and found that the diffusion-limited accumulation was a function of the depth, typical for 3D culture. Finally, we demonstrated the use of the sensor for Cu2+ ion detection in the brain of an APP/PS1 transgenic mouse model of Alzheimer's disease and tumor-bearing mice in response to injection (2 mg kg-1) of the liposomal form of the anticancer Cu-containing complex. Enhanced stability and selectivity, as well as distinct copper oxidation peaks, confirmed that the developed sensor is a promising tool for testing various types of biological systems. In summary, this research has demonstrated a minimally invasive electrochemical technique with high temporal resolution that can be used for the study of metabolism of copper or copper-based drugs in vitro and in vivo.


Assuntos
Doença de Alzheimer , Neoplasias , Camundongos , Humanos , Animais , Cobre , Doença de Alzheimer/diagnóstico , Íons , Técnicas Eletroquímicas
15.
Chempluschem ; : e202300692, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38052725

RESUMO

The title compound was synthesized by Ullmann cross-coupling in low yield as the first representative of [n]phenylene containing hydrocarbon and fluorocarbon rings. Stille/Suzuki-Miyaura cross-coupling reactions, as well as substitution of fluorine in suitable starting compounds, failed to give the same product. The geometric and electronic structures of the title compound were studied by X-ray diffraction, cyclic voltammetry and density functional theory calculations, together with Hirshfeld surface and reduced density gradient analyses. The crystal structure features head-to-tail π-stacking and other fluorine-related secondary bonding interactions. From the nucleus-independent chemical shifts descriptor, the four-membered ring of the title compound is antiaromatic, and the six-membered rings are aromatic. The Janus molecule is highly polarized; and the six-membered fluoro- and hydrocarbon rings are Lewis π-acidic and π-basic, respectively. The electrochemically-generated radical cation of the title compound is long-lived as characterized by electron paramagnetic resonance, whereas the radical anion is unstable in solution. The title compound reveals electrical properties of an insulator. On expanding its molecular scaffold towards partially fluorinated [n]phenylenes (n≥2), the properties presumably can be transformed into those of semiconductors. In this context, the title compound is suggested as a prototype scaffold for ambipolar materials for organic electronics and spintronics.

16.
Micromachines (Basel) ; 14(11)2023 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-38004876

RESUMO

We develop a compact physics model for hot-carrier degradation (HCD) that is valid over a wide range of gate and drain voltages (Vgs and Vds, respectively). Special attention is paid to the contribution of secondary carriers (generated by impact ionization) to HCD, which was shown to be significant under stress conditions with low Vgs and relatively high Vds. Implementation of this contribution is based on refined modeling of carrier transport for both primary and secondary carriers. To validate the model, we employ foundry-quality n-channel transistors and a broad range of stress voltages {Vgs,Vds}.

17.
Int J Mol Sci ; 24(22)2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-38003258

RESUMO

Inactivation of enzymes responsible for biosynthesis of the cell wall component of ADP-glycero-manno-heptose causes the development of oxidative stress and sensitivity of bacteria to antibiotics of a hydrophobic nature. The metabolic precursor of ADP-heptose is sedoheptulose-7-phosphate (S7P), an intermediate of the non-oxidative branch of the pentose phosphate pathway (PPP), in which ribose-5-phosphate and NADPH are generated. Inactivation of the first stage of ADP-heptose synthesis (ΔgmhA) prevents the outflow of S7P from the PPP, and this mutant is characterized by a reduced biosynthesis of NADPH and of the Glu-Cys-Gly tripeptide, glutathione, molecules known to be involved in the resistance to oxidative stress. We found that the derepression of purine biosynthesis (∆purR) normalizes the metabolic equilibrium in PPP in ΔgmhA mutants, suppressing the negative effects of gmhA mutation likely via the over-expression of the glycine-serine pathway that is under the negative control of PurR and might be responsible for the enhanced synthesis of NADPH and glutathione. Consistently, the activity of the soxRS system, as well as the level of glutathionylation and oxidation of proteins, indicative of oxidative stress, were reduced in the double ΔgmhAΔpurR mutant compared to the ΔgmhA mutant.


Assuntos
Proteínas de Escherichia coli , Escherichia coli , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Antibacterianos/farmacologia , Antibacterianos/metabolismo , NADP/metabolismo , Purinas/farmacologia , Purinas/metabolismo , Heptoses/química , Heptoses/metabolismo , Glutationa/metabolismo , Via de Pentose Fosfato
18.
Anal Chem ; 95(43): 15943-15949, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-37856787

RESUMO

ß-Amyloid aggregation on living cell surfaces is described as responsible for the neurotoxicity associated with different neurodegenerative diseases. It is suggested that the aggregation of ß-amyloid (Aß) peptide on neuronal cell surface leads to various deviations of its vital function due to myriad pathways defined by internalization of calcium ions, apoptosis promotion, reduction of membrane potential, synaptic activity loss, etc. These are associated with structural reorganizations and pathologies of the cell cytoskeleton mainly involving actin filaments and microtubules and consequently alterations of cell mechanical properties. The effect of amyloid oligomers on cells' Young's modulus has been observed in a variety of studies. However, the precise connection between the formation of amyloid aggregates on cell membranes and their effects on the local mechanical properties of living cells is still unresolved. In this work, we have used correlative scanning ion-conductance microscopy (SICM) to study cell topography, Young's modulus mapping, and confocal imaging of Aß aggregate formation on living cell surfaces. However, it is well-known that the cytoskeleton state is highly connected to the intracellular level of reactive oxygen species (ROS). The effect of Aß leads to the induction of oxidative stress, actin polymerization, and stress fiber formation. We measured the reactive oxygen species levels inside single cells using platinum nanoelectrodes to demonstrate the connection of ROS and Young's modulus of cells. SICM can be successfully applied to studying the cytotoxicity mechanisms of Aß aggregates on living cell surfaces.


Assuntos
Peptídeos beta-Amiloides , Microscopia , Espécies Reativas de Oxigênio/metabolismo , Peptídeos beta-Amiloides/química , Citoesqueleto/metabolismo , Membrana Celular/metabolismo , Amiloide/química , Fragmentos de Peptídeos/química
19.
Anal Chem ; 95(42): 15656-15664, 2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37815927

RESUMO

The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.

20.
J Proteome Res ; 22(10): 3290-3300, 2023 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-37683181

RESUMO

We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data-independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high-resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high-quality quantitative measurements across a wide dynamic range. We also use a newly developed extracellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5000 plasma proteins in a 60 min gradient with the Orbitrap Astral mass spectrometer.


Assuntos
Peptídeos , Proteômica , Proteômica/métodos , Espectrometria de Massas/métodos , Proteoma/metabolismo , Proteínas Sanguíneas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...